primary winding
英 [ˈpraɪməri ˈwɪndɪŋ]
美 [ˈpraɪmeri ˈwɪndɪŋ]
一次绕组;原绕组
英英释义
noun
- coil forming the part of an electrical circuit such that changing current in it induces a current in a neighboring circuit
- current through the primary coil induces current in the secondary coil
双语例句
- Some proposals are given: selecting TV with good excitation characteristic, reducing grounding number of TV in same network, keeping the symmetry of line-earth capacitance and paying attention to insulation coordination in neutral point of primary winding.
电磁式TV在使用中应注意选用励磁特性好的产品、减少同一系统中TV中性点接地的数量、保持系统三相对地电容的对称性,同时注意高压绕组中性点的绝缘配合问题。 - This paper introduces the importance of rising current at CT Primary Winding to the relay circuit check. And the method of rising current at CT primary winding and its application for switch and transformer bushing CTs in all kinds of operating modes are presented.
讲述了电流互感器一次升流在继电保护回路验收中的重要性,并介绍了各种运行方式下开关CT与变压器套管CT一次升流的应用方法。 - And also, the compensation current in the orthogonal phase of the primary winding current injected into the primary winding can adjust the equivalent resistance of the primary winding independently.
在补偿绕组中注入一个与主绕组电流相位正交的补偿电流,可以独立调节主绕组的等值电阻。 - It is found that the magnetizing inrush current could be influenced significantly by following factors; excitation characteristic, resistance in the primary winding of TV, line-earth capacitance and its symmetry as well as damping resistance of the network.
研究发现:TV的励磁特性和高压绕组直流电阻、系统三相对地电容及其对称性以及系统的阻尼率均对TV励磁涌流有明显影响。 - The terminal P2 of the primary winding is used as the static contact in the switch cabinet and it is with contact box.
本系列电流互感器为全封闭环氧树脂浇注结构,其一次绕组的P2端直接作为开关柜中的静触头,并带有触头盒。 - The harmonic compensation currents proportional to the harmonic current in the primary winding, which is detected real-timely, are injected to the multiple secondary winding of the transformer.
实时检测变压器原方绕组的谐波电流,通过逆变器产生与原方绕组谐波电流成比例的谐波补偿电流注入变压器副方多补偿绕组中。 - The unbalanced degrees of current in primary winding under different load conditions are discussed, which are based on the general expressions of negative phase sequence current.
结合负序电流的通用表达式,讨论了在不同负荷条件下的原边电流不平衡度。 - Situated within the coil's primary winding is the secondary winding.
与初级绕组对应的是次级绕组。 - Calculation of Dynamic Stability of Current Transformer with U Primary Winding
U形一次绕组电流互感器的动稳定计算 - Through various short-circuit current temperature rise test results, the transformer temperature, time, and a high degree of three curves, obtained directly within the thermal region transformer primary winding height of about 83.3%.
通过在不同短路电流条件下的温升试验,得到了变压器内部的温度与时间、纵向高度之间的关系曲线,得出变压器内部热区域主要集中在约绕组自下而上高度的83.3%区域。